|
.
Radiant Floor Heating and Cooling SystemsRadiant floor heating has been used for centuries. The Romans channeled hot air under the floors of their villas. The Koreans channeled hot flue gases under their floors before venting them up the chimney. In the 1930s, architect Frank Lloyd Wright piped hot water through the floors of many of his buildings. Some home builders’ surveys have shown that, if given a choice, most new home owners prefer radiant floor heat over other types of systems. Advantages of Radiant Floor HeatingMost people who own radiant floor heating feel that the most important advantages are comfort and quiet operation. Radiant floor systems allow even heating throughout the whole floor, not just in localized spots as with wood stoves, hot air systems, and other types of radiators. The room heats from the bottom up, warming the feet and body first. Radiant floor heating also eliminates the draft and dust problems associated with forced-air heating systems. Even heat distribution equates with lower heating bills. With radiant floor heating, you can set the thermostat several degrees lower. This is because the entire surface of the floor radiates about the same amount of heat that the human body does, making the occupant feel warm even though the air temperature might be only 65 o F (18 o C). It also radiates this heat for a longer period of time than a forced air system. Another advantage is that radiant systems do not increase the infiltration of outside air into the house structure as forced air systems generally do. Radiant floor heating also allows lower boiler temperatures allowing them to last longer (a 45 year life is not unusual). Radiant floors operate between 85-140o F (29-60o C), compared to other heating systems’ range of 130-160o F (54-71o C). Fuel saving of 15% to 20% over a forced air system is common. To some, the greatest advantage of radiant floor heating is aesthetic. The system is "invisible." There are no heat registers or radiators to obstruct furniture arrangements and interior design plans. Radiant floor systems also eliminate the fan noise of forced hot air systems. Types of Radiant Floor HeatingThere are three types of radiant floor heat: radiant air floors (air is the heat carrying medium); electric radiant floors; and hot water (hydronic) radiant floors. All three types can be further subdivided by the type of installation: those that make use of the large thermal mass of a concrete slab floor or lightweight concrete over a wooden subfloor (these are called "wet" installations); and those in which the installer "sandwiches" the radiant floor tubing between two layers of plywood or attaches the tubing under the finished or subfloor (dry installations). Because air cannot hold large amounts of heat, radiant air floors are not cost-effective in residential applications, and are seldom installed. Electric radiant floors are usually only cost-effective if your electric utility company offers time-of-use rates. Time-of-use rates allow you to "charge" the concrete floor with heat during off-peak hours (approximately 9 p.m. to 6 am). If the floor’s thermal mass is large enough, the heat stored in it will keep the house comfortable for eight to ten hours, without any further electrical input. This saves a considerable number of energy dollars compared to heating at peak electric rates during the day. Hydronic (liquid) systems are the most popular and cost-effective systems for heating-dominated climates. They have been in extensive use in Europe for decades. Hydronic radiant floor systems pump heated water from a boiler through tubing laid in a pattern underneath the floor. The temperature in each room is controlled by regulating the flow of hot water through each tubing loop. This is done by a system of zoning valves or pumps and thermostats. Wet installations are the oldest form of modern radiant floor systems. In a "wet" installation, the tubing is embedded in the concrete foundation slab, or in a lightweight concrete slab on top of a subfloor, or over a previously poured slab. If the new floor is not on solid earth, additional floor support may be necessary because of the added weight. You should consult a professional engineer to determine the floor’s carrying capacity. However, due to recent innovations in floor technology, "dry" floors have been gaining a lot of popularity over wet floors. Much of this is because a dry floor is faster and less expensive to build. There are several ways to make a dry radiant floor. Some "dry" installations involve suspending the tubing underneath the subfloor between the joists. This method usually requires drilling through the floor joists in order to install the tubing. Reflective insulation must also be installed under the tubes to direct the heat upward. Tubing may also be installed from above the floor, between two layers of subfloor. In these instances, the tubes are often in aluminum diffusers that spread the water’s heat across the floor in order to heat the floor more evenly. The tubing and heat diffusers are secured between furring strips (sleepers) which carry the weight of the new subfloor and finished floor surface. At least one company has improved on this idea by making a plywood subfloor material manufactured with tubing grooves and aluminum heat diffuser plates built into them. The manufacturer claims that this product makes a radiant floor system (for new construction) considerably less expensive to install and faster to react to room temperature changes. Such products also allow for the use of half as much tubing since the heat transfer characteristics of the floor is greatly improved over more traditional dry or wet floors. Floor CoveringsAlthough ceramic tile is the most common floor covering for radiant floor heating, almost any floor covering can be used. However, some perform better than others. Common floor coverings like vinyl and linoleum sheet goods, carpeting, wood or bare concrete is often specified. However, it is wise to always remember that anything that can insulate the floor also reduces or slows the heat entering the space from the floor system. This in turn increases fuel consumption. If you want carpeting, use a thin carpet with dense padding and install as little carpeting as possible. If some rooms, but not all, will have a floor covering then those rooms should have a separate tubing loop to make the system heat these spaces more efficiently. This is because the water flowing under the covered floor will need to be hotter to compensate for the floor covering. Most radiant floor references also recommend using laminated wood flooring instead of solid wood. This reduces the possibility of the wood shrinking and cracking from the drying effects of the heat. While solid wood flooring can be used, the installer is strongly advised to be very familiar with radiant floor systems before attempting to install natural wood flooring over a radiant floor system. Most manufacturers and manuals relating to radiant floors offer guidelines to help you resolve these issues. Types of TubingOlder radiant floor systems used either copper or steel tubing embedded in the concrete floors. Unless the builder coated the tubing with a protective compound, a chemical reaction between the metal and the concrete often led to corrosion of the tubing, and to eventual leaks. Major manufacturers of hydronic radiant floor systems now use cross-linked polyethylene (PEX) or rubber tubing with an oxygen diffusion barrier. These materials have proven themselves to be more reliable than the older choices in tubing. Fluid additives also help protect the system from corrosion. There have been recent reports of problems with rubber tubing produced by one chemical manufacturer. Leaks develop at the metal connections or fittings, and in some cases the tubing becomes rigid and brittle. It is still not clear what causes this problem, but theoretically excessively high water temperatures may be to blame. Tightening connections and clamps only temporarily fixes the leaks. Remember this problem only concerns a specific brand of rubber tubing. It does not have anything to do with the PEX tubing, which has performed very reliably for many decades. Since the price of copper tubing is considerably lower now than several years ago, it is again gaining some popularity because of it’s superior heat transfer abilities over plastic-based tubing. Controlling the SystemA radiant floor that uses a concrete slab takes many hours to heat up if it is allowed to become cold. This can be very inconvenient while waiting for the slab heat up so it can heat the space. Because of this, most radiant floor systems are not permitted to go into a very deep night setback. Depending on how the floor is constructed, the time it takes to re-heat the floor is sometimes longer than the occupant’s sleep period. Many floor systems are also controlled by a floor thermostat instead of a wall thermostat. The system is also often designed to keep the circulation pump(s) running while the thermostat only controls the boiler’s burner. Other, more sophisticated, types of controls sense the floor temperature, outdoor temperature, and room temperature to keep the home comfortable. Such a system may also use less fuel. Although radiant floor systems are usually heated by a boiler, they can also be heated with a geothermal heat pump. Such a system offers even greater energy savings in climates where the heating and cooling loads are similar in size. Another alternative for small houses, or those with small heating loads, is to use an ordinary gas water heater to supply the radiant floor system. Radiant Floor CoolingRadiant floor tubing can also be used to cool a house, but presently it is only appropriate for dry climates. The floor temperature is held at 68o F (20o C) by using either a small cooling machine (chiller) connected to the floor tubing or the steady 55o F (13 o C) temperature of the ground by means of an earth loop. In arid climates, the cool floor can be used to supplement or replace standard ducted air systems. However, in humid climates, problems with over-cooling the floor could lead to wet slippery surfaces and fungus growth. Radiant floor cooling technology is still in the experimental stages in most areas, but is rapidly gaining popularity in Europe where cooling needs are generally small. Cost of Radiant Floor HeatingThe cost of installing a hydronic radiant floor is approximately $4.00 to $6.00 per square foot ($40-$60 per square meter). This fluctuates depending on the size of the room, the type of installation, the floor covering, remoteness of the site, and the cost of labor. For additional information, contact:Hydronic Radiant Heating Division Radiant Panel Association BibliographyThe following publications provide additional information on radiant floor heating. This bibliography was reviewed in October 2001. Books and ReportsExisting Knowledge on Possibilities and Limitations of Radiant Floor Cooling- #4014, B. Olesen and D. Liedelt, 1996. Part of the January 25-29, 1997 ASHRAE Winter Meeting Technical Program. Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), 1791 Tullie Circle NE, Atlanta, GA 30329; Phone: (800) 527-4723; World Wide Web: ashrae.org How Come?: Hydronic Heating Questions We’ve Been Asking For More Than 100 Years (With Straight Answers), D. Holohan, Dan Holohan Associates, Inc. 1995. Available from Dan Holohan Associates, Inc., 63 North Oakdale Avenue, Bethpage, NY, 11714; Phone: (800) 853-8882; $20.00. Hydronic Radiant Heating: A Practical Guide for the Nonengineer Installer, D. Holohan, 1998. Available from Dan Holohan Associates (see How Come?…, above. 214 pp., 20.00. Modern Hydronic Heating, J. Siegenthaler, Delmar Publishers. 1995. Available from Delmar/Thomson Learning, Order Fulfillment, P.O. Box 6904, Florence, KY 41022; Phone: (800) 347-7707. $86.95. ISBN: 0-8273-6595-0. Pumping Away (And Other Really Cool Piping Options for Hydronic Systems), D. Holohan, Dan Holohan Associates, Inc. 1995. Available from Dan Holohan Associates, (see How Come?… above) $20.00. Articles"Adding Radiant-Floor Heating," J. Truini, Home Mechanix, (91:792) pp. 56-61, February 1995. "Can Radiant Floor Cooling Succeed Despite Design Limitation?" N. Nisson, Energy Design Update, (17:5) pp. 5-8, May 1997. "Canadian Study Details the Impact of Carpets on Radiant Floor Heating," Energy Design Update, (18:11) pp. 12-13, November 1998. "Electric-Radiant Floors," B. Kaercher, Jr. Fine Home Building, (No. 75) pp. 68-72, June/July 1992. "Heat at Your Feet," Home Mechanix, (89:780) November 1993. "Heatway, Goodyear Square Off in Court Over Radiant System Failures," Energy Design Update, (18:10) pp. 2-4, October 1998. "Hydronic Radiant Heat for Wood-Framed Floors," J. Siegenthaler, The Journal of Light Construction, (11:11) pp. 34-37, August 1993. "Mixing Forced-Air and Boiler Heat," R. Groff, Fine Home Building, (No. 85) pp. 86-87, January 1994. "Ohio Jury Says Goodyear’s Entran 2 Hosing Was Not Defective," Energy Design Update, (20:4) pp. 5-7, April 2000. "Radiant Floor Systems," C. Wardell, Custom Builder, (10:6) pp. 26-30, September/October 1995. "Radiant Slab Techniques," J. Siegenthaler, The Journal of Light Construction, (10:11) pp. 21-24, August 1992. "Radiant Slab on a Tight Budget," J. Siegenthaler, The Journal of Light Construction, (13:10) pp. 47-50, July 1995. "Radiant Subfloor Panels," J. Boucher, Journal of Light Construction, (18:7), pp. 75-81, April 2000. "Wet or Dry System? Here’s How They Compare," Air Conditioning, Heating & Refrigeration News, (196:4) p. 22, September 25, 1995.
The information in this brief was reviewed for accuracy in October 2001. EREC is operated by NCI Information Systems, Inc. for the National Renewable Energy Laboratory/U.S. Department of Energy. The content of this brief is based on information known to EREC at the time of preparation. No recommendation or endorsement of any non-US Government product or service is implied if mentioned by EREC. Your interest in energy efficiency and renewable energy is greatly appreciated. If we can be of further assistance, please feel free to contact us again. Energy Efficiency and Renewable Energy Clearinghouse
(EREC)
NOTICE |
|